Sedimentation by gravity stabilizes plasma glucose for up to 60 minutes

KJ Behan, M Johnston, M Dumas - American Society for Clinical …, 2013 - clsjournal.ascls.org
Objective: Glucose levels decrease in whole blood in vitro, but there are several methods
that minimize the loss, including special tubes and ice. This study evaluated whether …

Stability of glucose concentrations in frozen plasma

S Pleus, G Freckmann, A Baumstark… - Journal of Diabetes …, 2022 - journals.sagepub.com
Background: Conflicting information is available regarding the stability of glucose
concentrations in frozen plasma samples. Clinical trials could benefit from such long-term …

Effect of collection tube type on glucose stability in whole blood

J Jung, E Garnett, K Rector, P Jariwala… - Annals of Clinical & …, 2020 - Assoc Clin Scientists
Precise measurement of plasma glucose is essential in evaluation of diabetes. In vitro
decreases in glucose concentration due to glycolysis may lead to missed diabetes …

Plasma glucose measurement in diabetes: impact and implications of variations in sample collection procedures with a focus on the first hour after sample collection

H Chan, H Lunt, H Thompson, HF Heenan… - Clinical Chemistry and …, 2014 - degruyter.com
Background: Previous studies of participants with plasma glucose concentrations at or near
the glucose reference range demonstrate glucose loss following delayed separation and …

Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation

R Carey, H Lunt, HF Heenan, CMA Frampton… - Clinical …, 2016 - Elsevier
Objectives Blood collection tubes containing citrate lower pH, thereby inhibiting glycolysis.
When compared to other additives, they introduce an over-estimation in measured glucose …

The impact of different sample matrices in delayed measurement of glucose

V Roccaforte, M Daves, S Platzgummer, G Lippi - Clinical biochemistry, 2016 - Elsevier
Objectives This study was designed to compare glucose values in serum or lithium-heparin
samples immediately centrifuged with those paired specimens collected in tubes containing …

Preanalytical sample handling of venous blood: how to ensure your glucose measurement is accurate and reliable

AM Steele, KJ Wensley, E Brewer… - Practical …, 2013 - Wiley Online Library
Measurement of blood glucose is a standard biochemical test requiring optimum
preanalytical sample handling. Glucose measured in plasma from tubes containing sodium …

[HTML][HTML] It takes acid, rather than ice, to freeze glucose

SAA Van den Berg, MHM Thelen, LPW Salden… - Scientific reports, 2015 - nature.com
Plasma glucose levels provide the cornerstone of diabetes evaluation. Unfortunately,
glucose levels drop in vitro due to glycolysis. Guidelines provide suitable conditions which …

Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes

G Juricic, A Bakliza, A Saracevic… - Clinical Chemistry and …, 2016 - degruyter.com
Background: Delayed sample processing can affect accurate glucose measurement. Our
aim was to investigate the stability of glucose in samples collected in serum, sodium …

Deep lancing or overmanipulation?

GS Cembrowski, AK Füzéry - Journal of Diabetes Science …, 2017 - journals.sagepub.com
In this issue of the Journal of Diabetes Science and Technology, Heenan et al 1 compare 41
adults' average capillary blood glucose meter (BGM) glucoses to their single central …