Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Archive
  • Info for
    • Authors
    • Reviewers
  • About Us
    • About Us
    • Conflict of Interest
    • Informed Consent
    • Human and Animal Rights
  • More
    • Alerts
    • Feedback
    • Folders
  • ascls.org
    • ascls.org

User menu

  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
American Society for Clinical Laboratory Science
  • ascls.org
    • ascls.org
  • My alerts
  • Log in
  • My Cart
American Society for Clinical Laboratory Science

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Archive
  • Info for
    • Authors
    • Reviewers
  • About Us
    • About Us
    • Conflict of Interest
    • Informed Consent
    • Human and Animal Rights
  • More
    • Alerts
    • Feedback
    • Folders
  • Follow ASCLS on Twitter
  • Visit ASCLS on Facebook
  • Follow ASCLS on Instagram
  • RSS Feed
Research ArticleResearch and Reports

CLS Entry Level Competencies in Flow Cytometry

Diane Davis and Teresa Nadder
American Society for Clinical Laboratory Science January 2011, 24 (1) 29-34; DOI: https://doi.org/10.29074/ascls.24.1.29
Diane Davis
Medical Lab Science Program, Salisbury University, Salisbury, MD
CM
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: dldavis@salisbury.edu
Teresa Nadder
Department of Clinical Laboratory Sciences, Virginia Commonwealth University, Richmond, VA
CM
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

  1. Diane Davis, Ph.D. MLS, SC, SLS (ASCP)CM⇑
    1. Medical Lab Science Program, Salisbury University, Salisbury, MD
  2. Teresa Nadder, Ph.D. MLS (ASCP)CM
    1. Department of Clinical Laboratory Sciences, Virginia Commonwealth University, Richmond, VA
  1. Address for correspondence: Diane Davis, Ph.D. MLS, SC, SLS (ASCP)CM, Professor and Clinical Coordinator, Medical Lab Science Program, Salisbury University, Salisbury, MD,410-548-4787, (Fax) 410-548-9185, dldavis{at}salisbury.edu

Abstract

OBJECTIVE: To define entry level competencies in flow cytometry for CLS generalists.

DESIGN: Flow cytometry practitioners completed an electronic survey. Of 134 respondents, 131 met the desired demographics and were analyzed.

SETTING: Links to the survey were mailed to 3 listservs (Medlab-L, CLSEduc, Purdue Cytometry) and 2 email groups (ASCLS and AMLI). Participants completed the survey on-line.

PARTICIPANTS: The target population was flow cytometry practitioners who had experienced CLS education, earned certification and practiced at least one year in flow. Survey instructions asked participants not to complete the survey if they did not meet the demographic criteria.

MAIN OUTCOME MEASURES: A competency was deemed important at entry level if ≥50% of respondents agreed.

RESULTS: There was strong consensus (62-87%) that entry level CLS generalists should be able to 1) perform HIV CD4/CD8 monitoring, 2) gate cell populations using forward/side scatter and CD45/bright/dim markers and 3) evaluate specimen acceptability. Concepts to understand included leukemia immunophenotyping, quality control and instrument principles (61-83%). Most respondents (74%) felt that memorization of the leukemic CD panels was unnecessary. However, survey results indicated that the markers and cell type associations to memorize are CD3, CD4, CD8, CD19/20, CD34, CD45 and light chains. Hands-on experience with instruments was not identified as critical.

CONCLUSION: CLS educational programs can deliver almost all flow cytometry content in the didactic portion of the curriculum and can restrict CD marker memorization to a limited list. At minimum, HIV monitoring via CD4/CD8 counts and concepts of leukemia immunophenotyping should be included.

ABBREVIATIONS: AMLI- Association of Medical Laboratory Immunologists, ASCLS- American Society of Clinical Laboratory Science, ASCP- American Society of Clinical Pathology, CD – Cluster of differentiation, CLS - Clinical Lab Science, CLSEduc- Clseduc{at}list.apsu.edu, CLSI - Clinical Laboratory Standards Institute, DNA- Deoxyribonucleic acid, EDTA- Ethylenediaminetetraacetic acid, HIV- Human Immunodeficiency Virus, HLA- Human Leukocyte Antigen, Medlab-L- Medlab-L{at}listserv.buffalo.edu, NCA – National Credentialing Agency for Laboratory Personnel, PNH – Paroxysmal Nocturnal Hemoglobinuria, Purdue Cytometry - Cytometry{at}lists.purdue.edu.

    INDEX TERMS
  • CLS - Clinical Lab Science
  • Entry Level Competency
  • Flow Cytometry
  • © Copyright 2011 American Society for Clinical Laboratory Science Inc. All rights reserved.
PreviousNext
Back to top

In this issue

American Society for Clinical Laboratory Science: 24 (1)
American Society for Clinical Laboratory Science
Vol. 24, Issue 1
Winter 2011
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Back Matter (PDF)
  • Front Matter (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on American Society for Clinical Laboratory Science.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
CLS Entry Level Competencies in Flow Cytometry
(Your Name) has sent you a message from American Society for Clinical Laboratory Science
(Your Name) thought you would like to see the American Society for Clinical Laboratory Science web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
CLS Entry Level Competencies in Flow Cytometry
Diane Davis, Teresa Nadder
American Society for Clinical Laboratory Science Jan 2011, 24 (1) 29-34; DOI: 10.29074/ascls.24.1.29

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Request Permissions
Share
CLS Entry Level Competencies in Flow Cytometry
Diane Davis, Teresa Nadder
American Society for Clinical Laboratory Science Jan 2011, 24 (1) 29-34; DOI: 10.29074/ascls.24.1.29
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Barriers to Implementation of Quality Management Systems in Laboratories: Lessons from the Southern Africa TB Health Systems Project
  • Polyagglutination: Lectin Isolation for T-Activated Red Cells
  • Strength of Direct Antiglobulin Test as an Indicator of Disease Severity in Autoimmune Hemolytic Anemia
Show more Research and Reports

Similar Articles

Keywords

  • CLS - Clinical Lab Science
  • Entry Level Competency
  • Flow Cytometry

© 2025 The American Society for Clinical Laboratory Science

Powered by HighWire